Customer login Contact
Airflow circuit components Adjustable flow regulators 50-250Pa
RDR Ø 150 MM - 50-250Pa

RDR Ø 150 MM - 50-250Pa

< Back to Airflow circuit components - Adjustable flow regulators 50-250 Pa
Description Packg. * Code
RDR 50 m³/h Ø 150, 3 shims 8 9430
RDR 100 m³/h Ø 150, 2 shims 8 9431
RDR 120 m³/h Ø 150, 1 shim 8 9432
RDR 150 m³/h Ø 150, 1 shim 8 9433
RDR 180 m³/h Ø 150, 1 shim 8 9434
RDR 210 m³/h Ø 150 8 9435
RDR 240 m³/h Ø 150 8 9436
RDR 250 m³/h Ø 150 8 9437
RDR 270 m³/h Ø 150 8 9438
RDR 300 m³/h Ø 150 8 9439
* packaged quantities are shown for information purposes – All items can be ordered singly
RDR 50 m³/h Ø 150, 3 shims





RDR adjustable flow regulators are made from class MI plastic suitable for use at temperatures up to 60°C.

They can be set to the required flowrate in-situ to provide a predetermined airflow in a pressure range of 50–250 Pascals. 

The flow regulator fits directly inside a vertical or horizontal duct. For horizontal ducts ensure the bottom (“BAS”) direction indicated on the front of the regulator faces downward. A lip seal ensures air tightness.

Do not twist, push, or otherwise force the moving flap (the regulating element) when fitting. Compliance with the airflow direction indicated on the adapter is vital.


When the regulator is used in conjunction with an air diffusion vent, the distance between the vent and regulator must be at least equal to the duct diameter for air extraction and at least three times the duct diameter for air supply.

 



 



RDR regulator in air supply



RDR regulator in air extraction




 

The graphs opposite show the extraction flowrate in m³/hour of the RDR Ø150mm as a function of the pressure head in Pascals (regulation over a pressure range of 50–250Pa). 

The indicated values are averages within a variance of plus or minus 5%.


The regulators are characterized by their acoustic power level Lw in dB(A).



Flowrate
(m3/h)
 Lw in dB(A)
50 Pa 100 Pa 150 Pa 200 Pa
 120 30 37 39 42
150 33 37 41 45
180 34 40 44 47
210 34 40 42 44
240 35 41 44 47
270 37 43 45 49
300 33 37 42 45

Before fitting the regulator, the flowrate must be calibrated: 

Slacken off the locking screw on the flow regulation module with a Torx No.10 screwdriver

Align the setpoint marking (on the left or right of the module) with the required flowrate

Tighten the locking screw on the flow regulation module

 

Intermediate flowrates are possible by aligning the setpoint marking between graduations on the regulator.

 Flow regulator model Setpoint intervals
RDR ø 80 2,5 m3/h
RDR ø 100 -125 -160 5 m3/h
 RDR ø 200  10 m3/h
RDR ø 250 25 m3/h

RDR Ø 80 and 100 mm




Example of 50m³/h setting: 

setpoint marking on regulator aligned with “50” graduation on the left side

RDR Ø 125–250 mm




Example of 180m³/h setting: 

setpoint marking on regulator aligned with “180” graduation on the right side




 RDR Assembly Flowrates
(m3/h)
 Set flowrate
(m3/h)
 Code
 ø 80 RDR ø 80 15–50 50 9404
ø 100 RDR ø 80 + 1 shim 15–50 50 9409
ø 125 RDR ø 100 50–100 100 9413
ø 125 RDR ø 80 + 2 shims 15–50 50 9419
ø125 RDR ø 100 + 1 shim 50–100 100 9423
ø125 RDR ø 125 100–180 180 9427
ø 150 RDR ø 80 + 3 shims 15–50 50 9430
ø 150 RDR ø 100 + 2 shims 50–100 100 9431
ø150 RDR ø125 + 1 shim 100–180 180 9434
ø 150 RDR ø 150 180–300 300 9439
ø 160 RDR ø 80 + 3 shims 15–50 50 9440
ø 160 RDR ø 100 + 2 shims 50–100 100 9441



 RDR Assembly Flowrates
(m3/h)
 Set flowrate
(m3/h)
 Code
 ø 160 RDR ø 125 + 1 shim 100–180 180 9444
ø 160 RDR ø 150 180–300 300 9449
ø 200 RDR ø 80 + 4 shims 15–50 50 9455
ø 200 RDR ø 100 + 3 shims 50–100 100 9456
ø 200 RDR ø 125 + 2 shims 100–180 180 9457
ø 200 RDR ø 160 + 1 shim 180–300 300 9464
ø 200 RDR ø 200  300–500 500 9468
ø 250 RDR ø 100 + 4 shims 50–100 100 9475
ø 250 RDR ø125 + 3 shims 100–180 180 9476
ø 250 RDR ø 160 + 2 shims 180–300 300 9477
ø 250 RDR ø 200 + 1 shim 300–500 500 9483
ø 250 RDR ø 250 450–750 700 9488

 Adapter with seal

 Shim (to suit flowrate) 

 Body

 Regulating element

 Flow regulation module

 Regulation module locking screw


 RDR D1 (mm) D2 (mm) L (mm)
ø 80 76 76 55
ø 100 96 93 70






 Adapter with seal

 Shim (to suit flowrate) 

 Body

 Regulating element

 Flow regulation module

 Regulation module locking screw


 RDR D1 (mm) D2 (mm) L (mm)
 ø 125 120 117 86
ø 150 145 148 91
ø 160 145 148 91
ø 200 190 195 91
ø 250 235 245 120

The flow regulator must be kept accessible for cleaning and maintenance.