Customer login Contact
Extraction vents Humidity controlled ventilation system
ALIZÉ HYGRO TEMPO KITCHEN - Pushbutton - 12V

ALIZÉ HYGRO TEMPO KITCHEN - Pushbutton - 12V

< Back to Extraction vents - Humidity controlled ventilation system
Description Packg. * Code
12 1721
ALIZÉ HYGRO TEMPO battery op. (4.5 V) 6/40/90 HCP2 12 1722
ALIZÉ HYGRO TEMPO battery op. (4.5 V) 12/45/105 HCP3 12 1723
ALIZÉ HYGRO TEMPO battery op. (4.5 V) 10/45/120 HCP4 12 1724
ALIZÉ HYGRO TEMPO battery op. (4.5 V) 10/45/135 HCP5 12 1725
ALIZÉ HYGRO TEMPO battery op. (4.5 V) 12/45/135 HCP6 12 1726
Accessories
Open/close pushbutton for elec. operation (230V or batteries) 18 1790
Muffler ring for ALIZÉ HYGRO 18 1789
Adapter (plastic) Ø 125, D = 65 mm with seal 50 1793
Drywall 3-claw adapter Ø 125, L = 100 mm (with duct support seal) 30 1794
Through-slab plastic adapter Ø 125, L = 275 mm (sleeve L = 275 mm + duct support seal) 16 1796
* packaged quantities are shown for information purposes – All items can be ordered singly


Open/close pushbutton for elec. operation (230V or batteries)more information
Muffler ring for ALIZÉ HYGROmore information
Adapter (plastic) Ø 125, D = 65 mm with seal more information
Drywall 3-claw adapter Ø 125, L = 100 mm (with duct support seal)more information
Through-slab plastic adapter Ø 125, L = 275 mm (sleeve L = 275 mm + duct support seal)more information




ALIZÉ HYGRO TEMPO vents in ventilation systems are covered by Technical Appraisal No.14.5/17-2269 "VMC hygroréglable ALIZE 2018 for collective housing" and No 14.5/17-2268 "VMC hygroréglable ALIZE 2018 for individual housing”.


Kitchens: the ALIZÉ HYGRO TEMPO vent modulates airflow in line with the room’s ambient relative humidity and provides a 30-minute timed boost activated by the user.

This vent comes in 4 models for each flow rating:

ALIZÉ TEMPO cord (HCC): pull-cord operation

• ALIZÉ TEMPO elec 230V (HCE): pushbutton operation, 230V power supply

• ALIZÉ VISION 12V (HCBT): pushbutton operation, 12VAC power supply

• ALIZÉ VISION battery (HCP): controlled by presence detection, 3 x 1.5V battery operated

In addition to the general installation guidelines (see general information tab), the 12VAC power supply to the vent must be via a recessed 2-wire cable (2 x 1.5 mm²) leading to the back of the support plate (diagram opposite).
Class 2 electrical appliance.

We recommend screwing the vent support plate to the wall or ceiling through the 3 holes provided for this purpose on the plate.



 ALIZE HYGRO Lw in dB(A) Dn,e,w (C) in dB
 100 Pa  136 Pa

 160 Pa  

 *

 10/40/90 m3/h 31 35 37 55 59
 15/45/135 m3/h 31 35 37 55 58
*Vents with muffler ring (fitted into the duct behind the vent).

 Certified values

For other flowrates, use the values for the 15/45/135 vent.