ALIZÉ HYGRO ELEC with or without TEMPO timer - Pushbutton control or switch - 230V

ALIZÉ HYGRO ELEC with or without TEMPO timer - Pushbutton control or switch - 230V

< Back to Extraction vents - Flow modulation
Description Packg. * Code
12 3603
12 3606
12 3621
12 3622
12 3624
12 3653
ALIZÉ HYGRO TEMPO ELEC (230 V) 5/40/100 12 3656
ALIZÉ HYGRO TEMPO ELEC (230 V) 10/45/150 12 3671
ALIZÉ HYGRO ELEC (230V) without timer 5/40/100 12 3672
ALIZÉ HYGRO ELEC (230V) without timer 10/45/150 12 3674
Accessories
Open/close pushbutton for elec. operation (230V or batteries) 18 1790
Adapter (plastic) Ø 125, D =50 mm 75 1792
Adapter (plastic) Ø 125, D = 65 mm with seal 50 1793
Drywall 3-claw adapter Ø 125, L = 100 mm (with duct support seal) 30 1794
Through-slab plastic adapter Ø 125, L = 275 mm (sleeve L = 275 mm + duct support seal) 16 1796
* packaged quantities are shown for information purposes – All items can be ordered singly


Open/close pushbutton for elec. operation (230V or batteries)more information
Adapter (plastic) Ø 125, D =50 mmmore information
Adapter (plastic) Ø 125, D = 65 mm with seal more information
Drywall 3-claw adapter Ø 125, L = 100 mm (with duct support seal)more information
Through-slab plastic adapter Ø 125, L = 275 mm (sleeve L = 275 mm + duct support seal)more information




ALIZÉ extraction vents with flow modulation for offices provide a continuous base (“trickle”) airflow that is either fixed or varies in line with the room’s ambient relative humidity depending on the model chosen. Certain models also provide a boost extraction rate (at 80 Pa), with or without a time-out, that can be activated electrically (230 V) or triggered by presence detection (2 x 1.5V battery operated vents).

These vents come in 7 models.

ALIZÉ HYGRO TEMPO ELEC : 

Humidity controlled trickle flow and pushbutton-activated 30-minute timed boost, 230V power supply.

ALIZÉ HYGRO ELEC : 

Humidity controlled trickle flow and switch-operated boost, 230V power supply.

In addition to the general installation guidelines (see general information tab), the 230VAC power supply to the vent must be via a recessed 2-wire cable (2 x 1.5 mm²) leading to the back of the support plate (diagram opposite). This power supply must include a suitable protection device and be identified on the main distribution board in order to facilitate maintenance or repair of the vent.
Class 2 electrical appliance.

The vent must always be screwed to the wall or ceiling via the 2 holes provided for this purpose on the plate.


 ALIZE HYGRO
 Lw in dB (A)
 100 Pa 130 Pa 160 Pa
 5/40/100 m3/h 31 35 37
10/45/150 m3/h 31 35 37

The acoustic power levels above are with the humidity controlled extraction flowrate adjusted for maximum relative humidity..