Customer login Contact
In-frame ventilators Air intake silencers
SRT - Silencers, through-wall

SRT - Silencers, through-wall

< Back to In-frame ventilators - Air intake silencers
Description Packg. * Code
Window inlet kit
SRT 22/54 BL (22 m³/hour - 54 dB) 1 0975
SRT 30/54 BL (30 m³/hour - 54 dB) 1 0976
SRT 45/51 BL (45 m³/hour - 51 dB) 1 0977
SRT HY/52 BL (hygro 6/45 m³/hour - 52 dB) 1 0978
* packaged quantities are shown for information purposes – All items can be ordered singly

Kit SRT = SRT + air inlet vent (M-G or AIRA HY) + plastic adjusting sleeve + finish plate + 200mm PVC sleeve + GAP 125 6 + 2 screws + installation instructions (individual cardboard packaging)

SRT 22/54 BL (22 m³/hour - 54 dB)
Dn,e,w (Ctr) 
    
      
  51 to 54 dB


Cut-out Ø125 mm




The SRT made entirely from sheet steel fits into all types of infill after making a hole in the wall and sealing in a Ø125mm PVC sleeve. It is fitted in the interior of the infill in conjunction with an adjusting sleeve 

Model SRT 30/54 is used in conjunction with an M-G 22 or 30m³/h self-regulating air inlet.

Model SRT 45/51 is used in conjunction with an M-G 45m³/h self-regulating air inlet or an AIRA HY humidity controlled air inlet.

Make a hole in the wall and seal in a Ø125mm PVC sleeve sloping slightly toward the exterior.

Outside, once the sealing is complete, fit the louvre grille.

Fit the silencer to the wall with the 2 fastening lugs on the sides.

 

Make sure the sides of the SRT are lagged to ensure a thermal break.

The MPR sleeve must have at least 10mm of its length inside the SRT. Can be installed in infills of thickness 90+10mm to 110+10mm. For deeper infills a second adjusting sleeve will be required.

CETIAT test report 1014179-1
Acoustic insulation

 Type Dn,e,w (C) Dn,e,w (Ctr)
SRT 30/54 + M-G 22 55 dB 54 dB
SRT 30/54 + M-G 30 55 dB 54 dB
SRT 45/51 + M-G 45 52 dB 51 dB
SRT 45/51 + AIRA HY 53 dB 52 dB